Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Singapore medical journal ; : 373-378, 2023.
Article in English | WPRIM | ID: wpr-984213

ABSTRACT

INTRODUCTION@#Despite the challenges related to His bundle pacing (HBP), recent data suggest an improved success rate with experience. As a non-university, non-electrophysiology specialised centre in Singapore, we report our experiences in HBP using pacing system analyser alone.@*METHODS@#Data of 28 consecutive patients who underwent HBP from August 2018 to February 2019 was retrospectively obtained. The clinical and technical outcomes of these patients were compared between two timeframes of three months each. Patients were followed up for 12 months.@*RESULTS@#Immediate technical success was achieved in 21 (75.0%) patients (mean age 73.3 ± 10.7 years, 47.6% female). The mean left ventricular ejection fraction was 53.9% ± 12.1%. The indications for HBP were atrioventricular block (n = 13, 61.9%), sinus node dysfunction (n = 7, 33.3%) and upgrade from implantable cardioverter-defibrillator to His-cardiac resynchronisation therapy (n = 1, 4.8%). No significant difference was observed in baseline characteristics between Timeframe 1 and Timeframe 2. Improvements pertaining to mean fluoroscopy time were achieved between the two timeframes. There was one HBP-related complication of lead displacement during Timeframe 1. All patients with successful HBP achieved non-selective His bundle (NSHB) capture, whereas only eight patients had selective His bundle (SHB) capture. NSHB and SHB capture thresholds remained stable at the 12-month follow-up.@*CONCLUSION@#Permanent HBP is feasible and safe, even without the use of an electrophysiology recording system. This was successfully achieved in 75% of patients, with no adverse clinical outcomes during the follow-up period.


Subject(s)
Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Bundle of His , Follow-Up Studies , Stroke Volume , Retrospective Studies , Treatment Outcome , Cardiac Pacing, Artificial/adverse effects , Electrocardiography , Ventricular Function, Left/physiology
2.
Singapore medical journal ; : 430-433, 2023.
Article in English | WPRIM | ID: wpr-984204

ABSTRACT

INTRODUCTION@#MyDiagnostick is an atrial fibrillation (AF) screening tool that has been validated in the Caucasian population in the primary care setting.@*METHODS@#In our study, we compared MyDiagnostick with manual pulse check for AF screening in the community setting.@*RESULTS@#In our cohort of 671 candidates from a multi-ethnic Asian population, AF prevalence was found to be 1.78%. Of 12 candidates, 6 (50.0%) had a previous history of AF and another 6 (50.0%) were newly diagnosed with AF. Candidates found to have AF during the screening were older (72.0 ± 11.7 years vs. 56.0 ± 13.0 years, P < 0.0001) and had a higher CHADSVASC risk score (2.9 ± 1.5 vs. 1.5 ± 1.1, P = 0.0001). MyDiagnostick had a sensitivity of 100.0% and a specificity of 96.2%. In comparison, manual pulse check had a sensitivity of 83.3% and a specificity of 98.9%.@*CONCLUSION@#MyDiagnostick is a simple AF screening device that can be reliably used by non-specialist professionals in the community setting. Its sensitivity and specificity are comparable and validated across various studies performed in different population cohorts.


Subject(s)
Humans , Atrial Fibrillation/diagnosis , Heart Rate , Sensitivity and Specificity , Risk Factors , Electrocardiography , Mass Screening
SELECTION OF CITATIONS
SEARCH DETAIL